uRTEDemo_03_Nucleo-F446RE_SystemStates_10_Model

Output Section

.uRTE

Contains the data for uRTE internals

Warnings

Safety (1)

Safety Warnings for OutputSection .uRTE.
Safety warnings are related to the Requirements Layer, especially the SIL

.uRTE needs a SIL of SIL_1 but is using main for storage which has a achieved SIL of QM.

Diagrams

Safety

Required
SIL SIL_1

Properties

Base
Name.uRTE
Type OutputSection
Description

Contains the data for uRTE internals

User-IDOutputSection_11
UID_TR7aMOTUEeyrV5NXTwe27Q
configuration
InitializationUnInit
Generatetrue
Memory main
Section start symbolADRL_uRTE_URTE_BEGIN*
Section end symbolADRL_uRTE_URTE_END*
Symbols marked with * are automatically generated because no value was set.

Software Layer

Activation Engine

This OutputSection is used by the central activation engine as global Data storage.
Because of the global data storage of the RTE, all tasks access this section to manage their meta-data.

Tasks (3)

Tasks beeing associated with this OutputSection.

Task Core SIL Priority Software States Signals Init Hardware OutputSections Own TimeBase Stack

Task responsible for reading the button state

Arm® Cortex®-M4 SIL_1 6 - false .rtos.task.Button

Task responsible to let the LED blink

Arm® Cortex®-M4 SIL_1 4 - false .rtos.task.LED

Task responsible for sending out UART protocolls

Arm® Cortex®-M4 SIL_1 5 - false .rtos.task.UART